Table 50 Error Codes — Part Code 6005 (continued)
Part
Error
Code
Number
6005
8859
6005
8860
6005
8861
6005
8862
6005
8863
6005
8864
6005
8865
6005
8866
6005
8867
6005
8868
6005
8869
6005
8870
6005
8871
6005
8873
6005
8874
6005
8875
236 Remote Web Console for Storage System Messages and Error Codes
Error Message
Delete Pair (Pairsplit-S)
operation with C/T option
failed because some R-VOLs
in the group are in Duplex
(PAIR) or Pending (COPY)
status.
An internal error occurred.
An internal error occurred.
Wait a few minutes and retry
the Delete Pair (Pairsplit-S)
operation.
Unknown Error Code.
An internal error occurred.
An internal error occurred.
An internal error occurred.
An internal error occurred.
Duplicate CT Group# (A CT
Group has been already
active in MCU).
CT Group is not active.
CT Group Option cannot be
changed unless all
asynchronous pairs in the
group are suspended or
deleted.
The TrueCopy Asynchronous
for Mainframe function is not
installed in the specified
MCU.
XP Continuous Access
Asynchronous function is not
installed in the specified
MCU.
Invalid Timer Type option.
At least one asynchronous
pair is active in this group.
Recommended Action
The pair status does not allow
this operation. Refresh and
confirm the pair status
information on the window
first. If the R-VOL status is
valid, retry the operation.
Call HP technical support.
Call HP technical support.
The delete pair (Pairsplit-S)
operation failed. A few
minutes later, refresh the
window, confirm if the
specified volumes are in the
permissible status, and then
retry the operation.
The Remote Console
computer detected an
unknown error code. Call HP
technical support.
Call HP technical support.
Call HP technical support.
Call HP technical support.
Call HP technical support.
The operation failed because
a duplicate CT Group is
already active in the MCU.
Verify the status of the CT
group and retry the
operation.
Verify that the CT group is
active in the MCU.
The group operation failed
because the specified group
has at least one
asynchronous pair. Refresh
and check the XP Continuous
Access window.
Install TrueCopy
Asynchronous for Mainframe
in the MCU and retry the
operation.
Install the XP Continuous
Access Asynchronous
function in the MCU, and
then retry the operation.
Specify Local or None for the
timer type on the XP
Continuous Access window,
and then retry the operation.
Refresh and check the XP
Continuous Access window.
Severity
Failure
Level
Level
i
4
E
4
E
4
i
4
E
4
E
4
E
4
E
4
E
4
E
4
E
4
i
4
i
4
i
4
i
4
E
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents