HP XP20000/XP24000 Manual page 252

Hp storageworks xp24000/xp20000 remote web console error codes (ae131-96086, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

Table 50 Error Codes — Part Code 6005 (continued)
Part
Error
Code
Number
6005
68872
6005
68873
6005
68874
6005
68875
6005
68876
6005
68877
6005
68878
6005
68879
6005
68880
6005
68881
6005
68882
6005
68883
6005
68889
6005
68890
252 Remote Web Console for Storage System Messages and Error Codes
Error Message
The operation failed, because
the specified volume was not
a volume of External Storage.
The operation failed, because
the specified volume was
defined in the LU path.
The operation failed, because
the emulation type of the
specified volume was not
OPEN-V.
The operation failed, because
the specified volume was a
LUSE volume.
The operation failed, because
the parity group of the
specified external volume
was composed of two or
more LDEVs.
The operation failed, because
the specified volume was a
reserved volume of Business
Copy.
The operation failed, because
the specified volume was a
journal volume.
The operation failed, because
the specified volume was a
pool volume.
The operation failed, because
the specified volume was
used for Auto LUN.
The operation failed, because
the specified volume was
used as a system disk.
The operation failed, because
the quorum disk was
inaccessible.
The operation failed, because
the specified serial number
was different from the serial
number of the quorum disk.
The operation failed, because
the quorum disk was blocked.
The operation failed, because
the specified serial number
was not RCU but MCU.
Recommended Action
Check the volume setting.
Specify another volume, or
release the LU path definition.
Check the emulation type of
the volume.
Select another volume, or
release the LUSE setting.
Select a parity group of an
external volume that is
composed of a single LDEV.
Select another volume, or
release the XP Business Copy
setting.
Select another volume, or
release the journal volume
setting.
Select another volume, or
release the pool volume
setting.
Select another volume, or
release the XP Auto LUN
setting.
Select another volume.
Check the following
conditions on the external
volume specified for the
quorum disk.
If it is blocked.
If a path is defined.
Check the serial number of
the quorum disk.
Check the status of the
quorum disk.
Specify the serial number of
the RCU, and retry the
operation.
Severity
Failure
Level
Level
W
0
W
0
W
0
W
0
E
5
W
0
W
0
E
5
E
5
W
0
W
0
W
0
W
0
W
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents