HP XP20000/XP24000 Manual page 240

Hp storageworks xp24000/xp20000 remote web console error codes (ae131-96086, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

Table 50 Error Codes — Part Code 6005 (continued)
Part
Error
Code
Number
6005
8922
6005
8923
6005
8924
6005
8926
6005
8927
6005
8929
6005
8930
6005
8931
6005
8932
6005
8934
6005
8936
6005
8937
240 Remote Web Console for Storage System Messages and Error Codes
Error Message
The specified MCU does not
support serial remote copy
connections.
The specified RCU does not
support serial remote copy
connections.
Logical paths exist on the
RCU port.
The specified R-VOL is
prohibited to use by Volume
Security.
The specified M-VOL is
prohibited to use by Volume
Security.
Invalid port type.
Logical paths exist on the
RCU port.
Logical paths exist on the
RCU port.
Since the configuration
definition of the specified
LDKC number or CU number
does not exist, the logical
paths between MCU and
RCU cannot be established.
The Paircreate operation
failed because specified
R-VOL is the NAS system
volume.
The Paircreate operation
failed. The version of the
specified RCU does not
support XP Continuous Access
with the NAS volume.
The Paircreate operation with
the Fibre Channel remote
copy connection failed
because there are pairs with
the serial remote copy
connection in the specified
MCU.
Recommended Action
Confirm whether the MCU
supports serial remote copy
connections. Install the
microcode of version that
supports serial remote copy
connections, or use fibre
remote copy connections.
Confirm whether the RCU
supports serial remote copy
connections. Install the
microcode of version that
supports serial remote copy
connections, or use fibre
remote copy connections.
Delete the logical paths on
the specified port, and retry
the operation.
Confirm the status of Volume
Security of the specified
R-VOL.
Confirm the status of Volume
Security of the specified
M-VOL.
Check the port status and
retry.
Delete the logical paths on
the specified port, and retry
the operation.
Delete the logical paths on
the specified port, and retry
the operation.
Check whether the specified
LDKC number or CU number
is defined as configuration
information for the MCU.
Check the configuration of
the specified R-VOL.
Check the microcode version
of the RCU.
Delete all the pairs with the
serial remote copy connection
in the specified MCU, and
then retry the operation.
Severity
Failure
Level
Level
E
4
E
4
E
4
E
4
E
4
W
4
E
4
E
4
W
5
i
4
i
4
i
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents