Table 54 Error Codes — Part Code 6505 (continued)
Part
Error
Error Message
Code
Number
6505
58323
The Add Pair (Paircreate)
operation failed because the
specified primary data
volume was being used by
XP Continuous Access
Asynchronous or TrueCopy
Asynchronous for Mainframe.
6505
58324
The Add Pair (Paircreate)
operation failed because the
specified primary data
volume was a P-VOL of XP
Continuous Access XP
External Storage Access
Manager, or an M-VOL of
TrueCopy for Mainframe.
6505
58325
The specified primary data
volume is used by XP
Continuous Access, XP
External Storage Access
Manager, or TrueCopy for
Mainframe. The operation
failed because the status of
the XP Continuous Access
pair, the XP External Storage
Access Manager pair, or the
TrueCopy for Mainframe pair
was inappropriate.
6505
58326
The Add Pair (Paircreate)
operation failed because the
specified primary data
volume was shared by XP
Continuous Access (or
TrueCopy for Mainframe)
and Business Copy (or
ShadowImage for
Mainframe).
6505
58327
The Add Pair (Paircreate)
operation failed because the
specified primary data
volume was a LUSE volume.
6505
58328
The Add Pair (Paircreate)
operation or the Resume Pair
(Pairresync) operation cannot
be performed because the
journal cache for the restore
journal group is not empty
and contains data.
Recommended Action
Specify another primary data
volume, and retry the
operation.
Confirm the controller type of
the RCU.
Check the status of the
specified primary data
volume in XP Continuous
Access, XP External Storage
Access Manager, or
TrueCopy for Mainframe
window.
If the primary data volume is
in PSUS, PSUE, or Suspend
status, restore the volume,
and then retry the operation.
If the primary data volume is
in COPY or Pending status,
retry the operation after the
status of the volume changes
to PAIR or Duplex.
Specify another primary data
volume, and retry the
operation.
Specify another primary data
volume, and retry the
operation.
Call HP technical support.