HP XP20000/XP24000 Manual page 269

Hp storageworks xp24000/xp20000 remote web console error codes (ae131-96086, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

Table 54 Error Codes — Part Code 6505 (continued)
Part
Error
Error Message
Code
Number
6505
8731
The existing logical addresses
are not the same.
6505
8733
XP Continuous Access Journal
or Universal Replicator for
Mainframe is not installed in
the subsystem.
6505
8734
XP Continuous Access Journal
or Universal Replicator for
Mainframe is not installed in
the remote subsystem.
6505
8735
The serial number or the
controller ID of the remote
subsystem is incorrect.
6505
8736
The specified remote
subsystem contains journal
groups or data volume pairs
for remote copy operations.
6505
8737
An internal error occurred.
6505
8742
Pinned track(s) exists in the
primary data volume.
6505
8743
Pinned track(s) exists in the
secondary data volume.
Recommended Action
Delete the DKC once, and
then add the DKC using the
same logical address.
XP Continuous Access Journal
or Universal Replicator for
Mainframe must be installed
in the storage system when
you create a path or a pair
for XP Continuous Access
Journal or Universal
Replicator for Mainframe.
Install XP Continuous Access
Journal or Universal
Replicator for Mainframe in
the storage system.
XP Continuous Access Journal
or Universal Replicator for
Mainframe must be installed
in the remote storage system
when you create a path or a
pair for XP Continuous
Access Journal or Universal
Replicator for Mainframe.
Install XP Continuous Access
Journal or Universal
Replicator for Mainframe in
the remote storage system.
Check the serial number and
the controller ID of this remote
storage system and already
registered remote storage
systems, and then specify the
correct values.
If the specified values are
correct, check the cable
connection of the remote
storage system. If the problem
persists, call HP technical
support.
Delete data volume pairs of
the specified remote storage
system. Then delete journal
groups, if any. Ensure that
there are no data volume
pairs and journal groups,
and then retry the operation.
Check the SSB log, and then
call HP technical support.
Check the status of the
pinned tracks in the primary
data volume, and clear the
pinned tracks.
Check the status of the
pinned tracks in the
secondary data volume, and
clear the pinned tracks.
Remote Web Console Error Codes 269
Severity
Failure
Level
Level
i
4
i
4
i
4
E
4
W
0
E
4
W
4
W
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents