HP XP20000/XP24000 Manual page 178

Hp storageworks xp24000/xp20000 remote web console error codes (ae131-96086, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

Table 39 Error Codes — Part Code 3305 (continued)
Part
Error
Code
Number
3305
65692
3305
65693
3305
65694
3305
65696
3305
65728
3305
65730
3305
65740
178 Remote Web Console for Storage System Messages and Error Codes
Error Message
The format processing for the
added volume has not been
executed because the
specified volumes contain
volumes that quick format
cannot be executed Execute
the format processing for the
added volume.
The format processing for the
added volume has not been
executed because there is no
System Disk area for Quick
Format, the capacity of the
System Disk is insufficient, or
the System Disk is blocked.
Execute the format
processing for the added
volume. To execute quick
formatting, execute after the
system disk has been added,
or the blocked System Disk
is restored.
The format processing for the
added volume has not been
executed because the
number of parity groups
being quick formatted has
exceeded the maximum.
Execute the format
processing for the added
volume. To execute quick
format processing, execute
after the quick format
processing for other parity
groups has completed.
A failure occurred while
formatting or quick
formatting.
The specified volume is not
available to execute VLL
operation (Install CV, Make
Volume, Volume Initialize,
and Volume to Space).
The system disk cannot be
set on the specified volume.
The configuration changing
processes are conflicting at
DKC.
Check if the configuration
changing process by RAID
Manager, Auto LUN or
Quick Restore is not in the
operation, and then retry the
operation.
Recommended Action
Execute the format processing
for the added volume.
Execute the format processing
for the added volume.
Execute Quick Format after
the system disk is added, or
the blocked System Disk is
restored.
Execute the format processing
for the added volume. The
quick format processing can
be executed after the quick
format processing for other
parity groups has completed.
Cancel the format or quick
format processing from the
SVP, and then execute the
format or quick format
processing again.
Check the specified volume.
Check the specified volume
and retry the operation.
The configuration changing
processes are conflicting at
DKC.
Check if the configuration
changing process by RAID
Manager, XP Auto LUN, or
Quick Restore is not in the
operation, and then retry the
operation.
Severity
Failure
Level
Level
W
6
E
6
W
6
E
2
E
2
E
6
E
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents