Table 50 Error Codes — Part Code 6005 (continued)
Part
Error
Error Message
Code
Number
6005
8755
The serial number, SSID or
CU number of the RCU is
invalid.
6005
8756
MCU disk array cache is not
active.
6005
8757
One side of the Cache or
shared memory on the MCU
is blocked.
6005
8758
Unexpected error on MCU.
6005
8759
RCU Subsystem Cache status
is not active.
6005
8760
M-VOL and R-VOL Track
Formats do not match.
6005
8761
The operation failed because
the specified volumes were in
one of the following statuses:
The emulation types of
M-VOL and R-VOL do not
match.
The capacities of M-VOL
and R VOL do not match.
LUSE volume is specified
for M VOL and R-VOL,
and the capacity of each
volume combined in the
LUSE does not match each
other.
6005
8762
R-VOL Device Cache status is
not active.
6005
8763
R-VOL DFW status is not
active.
6005
8764
The specified R-VOL is not
usable.
Recommended Action
Take either of the following
actions:
1.
Check the serial number,
SSID or CU number of the
RCU, and retry the
operation with correct
parameters.
2.
Check the connection LCP
ports of the RCU. Connect
the path correctly, and
retry the operation.
Check the storage system
cache status of the MCU from
the host. If it is off, set it on
and retry. If it cannot be set
on, call HP technical support.
There is an invalid cache or
shared memory status on the
MCU. Check the status and
recover the cache or shared
memory, and then retry the
operation.
Call HP technical support.
Call HP technical support.
Check the track formats of the
specified M-VOL and R-VOL.
Verify the following items for
the specified M-VOL and
R-VOL.
If the emulation types
match each other.
In the case of LUSE
volume, if the capacity of
each volume combined in
the LUSE matches each
other.
In the case of mainframe
system, if the capacity of
copy target is larger than
that of copy source.
Check the device cache
status of R-VOL from host. If
it is off, set it on and retry. If
it cannot be set on, call HP
technical support.
Check the DFW status of the
R-VOL from the host. If it is
off, set it on and retry. If it
cannot be set on, call HP
technical support.
Confirm the status of the
specified R-VOL.
Remote Web Console Error Codes 225
Severity
Failure
Level
Level
E
4
i
4
W
4
W
4
i
4
i
4
W
4
i
4
i
4
W
4