HP XP20000/XP24000 Manual page 354

Hp storageworks xp24000/xp20000 remote web console error codes (ae131-96086, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

Table 61 Error Codes — Part Code 7005 (continued)
Part
Error
Code
Number
7005
8608
7005
8609
7005
8610
7005
861 1
7005
8612
7005
8613
7005
8614
7005
8615
7005
8618
7005
8619
7005
8622
354 Remote Web Console for Storage System Messages and Error Codes
Error Message
The specified S-VOL is not
defined.
The specified volume is not
set as a reserved volume.
The S-VOL is a target volume
for Auto LUN.
The specified volume is an
S-VOL.
The specified volume is not
an S-VOL.
The RAID level of the
specified S-VOL is not
supported.
The command has been
rejected because the
specified S-VOL is used as
P-VOL of XP Continuous
Access pair or XP External
Storage Access Manager
pair.
The command has been
rejected because the
specified S-VOL is used as
S-VOL of XP Continuous
Access pair or XP External
Storage Access Manager
pair.
The S-VOL is already defined
as a P-VOL.
The specified S-VOL is
defined as a source volume
for Auto LUN.
The command has been
rejected because the
specified volume is used as
P-VOL of XP Continuous
Access pair or XP External
Storage Access Manager
pair.
Recommended Action
Refresh the screen, and retry
the operation.
Check the contents, and retry.
Release the XP Auto LUN
setting.
Check the volume status.
Check the volume status.
Specify the volume number
of the supported RAID level.
The requested command
cannot be executed in the
current status of XP
Continuous Access pair or XP
External Storage Access
Manager pair. See the
section about the sharing XP
Business Copy volumes in the
HP StorageWorks
XP24000/XP20000 Business
Copy Software User Guide
for the relation between the
state of XP Continuous Access
pair or XP External Storage
Access Manager pair and the
XP Business Copy operations.
The S-VOL of XP Continuous
Access pair or XP External
Storage Access Manager
pair cannot be used as S-VOL
of XP Business Copy. Specify
another volume.
Check the volume number.
Release the XP Auto LUN
setting.
The P-VOL of XP Continuous
Access pair or XP External
Storage Access Manager
pair cannot be used as a
reserved volume. Specify
another volume.
Severity
Failure
Level
Level
i
0
i
0
i
0
i
0
i
0
i
0
W
5
W
5
i
0
i
0
W
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents