Advertisement

Table 54 Error Codes — Part Code 6505 (continued)
Part
Error
Code
Number
6505
58031
6505
58032
6505
58033
6505
58034
6505
58035
6505
58036
6505
58037
6505
58038
6505
58039
6505
58040
6505
58064
6505
58065
6505
58066
6505
58067
6505
58068
6505
58069
278 Remote Web Console for Storage System Messages and Error Codes
Error Message
The threshold for starting
creation of asynchronous
journal must be larger than
the threshold for ending
creation of asynchronous
journal.
The threshold for starting
creation of synchronous
journal must be larger than
the threshold for ending
creation of synchronous
journal.
The total cache capacity is
incorrect.
The operation is impossible
because the subsystem is
being powered on.
No more journal volumes can
be registered, or too many
volumes are selected.
The device emulation type of
the specified volume is not
supported.
The specified journal group
cannot be deleted because a
data volume exists.
No more path group IDs can
be registered.
The specified volume is
already used as a journal
volume or a data volume.
An internal error occurred.
Too many requests. Reduce
the number of requests to be
processed at one time. After
that, retry the operation.
Invalid parameter (LDEV
number).
Invalid parameter (Journal
Group number).
Invalid parameter (Mirror ID).
Invalid parameter (Journal
Control).
Invalid parameter (Suspend
Condition-Journal Full).
Recommended Action
Ensure that the threshold for
starting creation of
asynchronous journal is
larger than the threshold for
ending creation of
asynchronous journal.
Ensure that the threshold for
starting creation of
synchronous journal is larger
than the threshold for ending
creation of synchronous
journal.
Check the cache capacity of
the primary and secondary
storage systems.
Wait until the storage system
is ready.
Check the number of the
journal volumes in the
specified journal groups.
Also, check the number of the
selected volumes.
Check the emulation type of
the specified volume.
Check the status of the
specified journal group.
Check the number of
registered path group IDs.
Specify another volume.
Check the SSB log, and then
call HP technical support.
Reduce the number of
requests to be processed at
one time. Then retry the
operation.
Check the specified LDEV
number.
Check the specified journal
group number.
Check the specified mirror ID.
Check the specified JNL
Control parameter.
Check the specified Suspend
Condition parameter.
Severity
Failure
Level
Level
i
0
i
0
i
0
i
0
i
0
i
0
i
0
i
0
i
0
E
4
i
0
i
0
i
0
i
0
i
0
i
0

Hide quick links: