Table 39 Error Codes — Part Code 3305 (continued)
Part
Error
Code
Number
3305
1913
3305
1914
3305
1919
3305
1922
3305
2004
3305
2005
3305
201 1
3305
2015
3305
2022
3305
2081
172 Remote Web Console for Storage System Messages and Error Codes
Error Message
The setting cannot be made
because the specified LDEV
is a remote command
device.
The number of V-VOL(s) has
exceeded the maximum
number of V-VOL(s) that can
be set in a storage system.
The newly added LDEV has
not been formatted. Check
the blocked LDEV and format
the LDEV.
The number of XP Thin
Provisioning volume(s) has
exceeded the maximum
number of XP Thin
Provisioning volume(s) that
can be set in a disk
subsystem.
An error occurred during
SVP processing. If this
problem persists, call HP
technical support.
An error occurred during
SVP processing. If this
problem persists, call HP
technical support.
The status of the storage
system requires maintenance
(for example, the subsystem
is blocked, the shared
memory is inconsistent, or
some other problem occurs).
Call HP technical support.
An error occurred while
connecting to the subsystem.
Wait for a while, and then
retry the operation.
An error occurred during
SVP processing. If this
problem persists, call HP
technical support.
An error occurred during a
VLL operation to add or
delete customized volumes.
Wait for a while, and then
retry the operation.
Recommended Action
Check the setting.
Correct the settings, and then
retry the operation.
Check the blocked LDEV and
format the LDEV.
Correct the settings, and then
retry the operation.
If this problem persists, call
HP technical support.
If this problem persists, call
HP technical support.
Check the status of the disk
storage system (for example,
the storage system is blocked,
the shared memory is
inconsistent, or some other
problem occurs). If this
problem persists, call HP
technical support.
A communication error
occurs. If the error occurs
after retrying, call HP
technical support.
If this problem persists, call
HP technical support.
If this problem persists, call
HP technical support.
To perform a VLL operation
on an external volume, check
the status of the path to the
external volume.
Severity
Failure
Level
Level
E
6
E
6
W
6
E
6
E
2
E
2
E
6
E
6
E
2
E
6