Table 56 Error Codes — Part Code 6510 (continued)
Part
Error
Error Message
Code
Number
6510
59043
The number of journal
volumes in some journal
groups exceeds the
maximum. Adjust the number
of journal volumes.
6510
59100
The same volume is stored
more than once in the
Preview list.
Use the sort function to
identify volumes with the
same LDKC number, the same
CU number and the same
LDEV number.
6510
59103
There is no volume that can
be registered or deleted.
6510
59104
The specified parity group
does not contain volumes that
can be registered or deleted
as journal volumes.
6510
59108
The master journal group
number for the specified data
volume exceeds 0x0F.
6510
591 1 1
There are two or more CLPR
numbers for the specified
data volume. In this
operation, specify only one
CLPR number.
6510
591 12
The CLPR number of the
specified data volume is
different from the CLPR
number of the data volume in
the Preview list. In this
operation, specify only one
CLPR number.
6510
591 13
There are two or more CLPR
numbers for the specified
volume, or you tried to
register a volume different
from the CLPR number of an
existing volume. Two or more
CLPR numbers cannot exist in
one journal group.
Recommended Action
Reduce the number of journal
volumes to be registered, or
increase the number of
journal volumes to be
deleted.
Use the sort function to
identify volumes with the
same LDKC number, the same
CU number and the same
LDEV number.
Create a volume that can be
used as a journal volume. To
do this, add a volume or use
some other way.
Specify another parity group.
Check the master journal
group number for the
specified data volume.
Change the journal group
number if you are performing
an Add Pair (Paircreate)
operation.
Delete the data volume from
the Preview set list if you are
performing a Resume Pair
(Pairresync) operation.
Check the CLPR number for
the specified data volume,
and specify only one CLPR
number.
Specify only the volume that
has the same CLPR number
as the CLPR number of the
volume in the Preview list.
Check the CLPR number of
the specified volume, and
check the CLPR numbers of
any existing volumes. Specify
the volume so that there is
only one CLPR number in the
journal group.
Remote Web Console Error Codes 327
Severity
Failure
Level
Level
W
0
W
0
W
0
W
0
W
5
W
5
W
5
W
5

Hide quick links: