Table 54 Error Codes — Part Code 6505 (continued)
Part
Error
Error Message
Code
Number
6505
58606
Journal groups cannot be
deleted from the extended
consistency group (EXCTG),
because the specified EXCTG
was not registered.
6505
58607
Journal groups cannot be
deleted from the extended
consistency group (EXCTG),
because the specified journal
group was not registered.
6505
58608
The Resume Pair operation
failed. The primary subsystem
does not support the
extended CT group (EXCTG)
function, though the restore
journal group belongs to an
EXCTG.
6505
58609
The timer type cannot be
changed because the
specified journal group
belongs to an extended
consistency group (EXCTG).
6505
58610
The parameter specified in
the extended consistency
group (EXCTG) operation is
invalid.
6505
5861 1
The specified operation failed
because the microcode
exchange was in progress on
the subsystem in the extended
consistency group (EXCTG).
6505
58612
The previously executed
update processing of the
extended consistency group
(EXCTG) has not completed.
Wait for a while, and then
retry the operation.
6505
58613
The command device is
specified incorrectly.
6505
58614
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the specified journal
group was not registered.
6505
58615
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the specified mirror
ID was not registered in the
specified journal group.
Recommended Action
Check the status of the
specified extended
consistency group (EXCTG).
Check the journal groups in
the specified extended CT
group.
Update the microcode of the
primary storage system to the
version which supports the
EXCTG function.
Check that the specified
journal group belongs to an
extended consistency group
(EXCTG).
Refresh the window, and then
retry the operation. If this
problem persists, call HP
technical support.
Retry the operation after the
microcode exchange
completes.
Wait a few seconds, and
then retry the operation.
Check whether the specified
CU number and the LDEV
number indicate a command
device.
Check whether the specified
journal group is registered.
Check the mirror ID of the
specified journal group.
Remote Web Console Error Codes 297
Severity
Failure
Level
Level
W
0
W
0
W
0
W
0
W
0
W
0
W
0
W
0
W
0
W
0

Hide quick links: