Table 67 Error Codes — Part Code 8105 (continued)
Part
Error
Code
Number
8105
1 135
8105
1 136
8105
1 137
8105
1 140
8105
1 170
8105
1 181
8105
1 183
8105
1 184
8105
1 193
8105
1 198
8105
1201
402 Remote Web Console for Storage System Messages and Error Codes
Error Message
An error occurred. If this
problem persists, call HP
technical support.
An error occurred. If this
problem persists, call HP
technical support.
Failed to from a LUSE volume
because the number of LUSE
volumes exceeds the
maximum that can be set in
a disk array subsystem.
Nothing is set. Create a
setting and then execute it.
The volume cannot be
configured as a command
device because the volume
does not have Read/Write
attribute.
The specified path cannot be
added, because the volume
is used by a XP Continuous
Access pair.
The port information is
inconsistent with PCB mode
information.
The port information is
inconsistent with PCB mode
information.
You cannot add paths to XP
Continuous Access or
Business Copy pair volumes.
Since a path is defined to an
external LU, you cannot set
high-speed mode.
The selection of High Speed
mode/MIX mode is invalid.
The specified port cannot be
changed to High Speed
mode/MIX mode.
Recommended Action
When the PORT information
(Fibre Address/Fibre
Topology/Channel Speed) is
set, multiple change
instructions are set to the
same port. The error does not
occur normally because it is
guarded in the screen. In the
unlikely event that this error
occurs, contact HP technical
support.
When CHA high-speed mode
is set, multiple change
instructions are set to the
same port. The error does not
occur normally because it is
guarded in the screen. In the
unlikely event that this error
occurs, contact HP technical
support.
The configuration information
has been already changed.
Check the settings, and
request the setting of the
configuration information
again.
Release the Port Group
setting.
Connect settings, and then
retry.
Correct the specified
contents, and request again.
Correct the port information
or the PCB mode information.
Correct the port information
or the PCB mode information.
Correct the settings, and then
retry.
Correct the settings, and then
retry.
Change the parameter to a
path where the High Speed
mode/MIX mode can be set,
and then retry the operation.
Severity
Failure
Level
Level
E
2
E
2
E
6
W
6
E
6
E
6
W
0
W
0
E
6
E
6
E
5