Table 50 Error Codes — Part Code 6005 (continued)
Part
Error
Error Message
Code
Number
6005
8714
An internal error occurred.
6005
8715
Invalid number of paths.
6005
8717
Invalid Destination Link
Address.
6005
8718
The specified logical path
already exists.
6005
8719
Invalid RCU serial number,
SSID, Link Address or
Controller ID.
6005
8720
Too many RCUs. (Four RCUs
are the maximum)
6005
8721
Path not completely
established.
6005
8722
Failure during path creation.
6005
8723
The Edit Path operation was
rejected because the
specified path is the last path
of some XP Continuous
Access pairs.
6005
8724
Specified number of paths is
less than the minimum
specified on RCU Option
screen.
6005
8725
Current microprogram
version does not support the
specified operation.
6005
8727
The number of minimum
paths exceeds the number of
normal paths.
Recommended Action
Call HP technical support.
The specified number of
paths is not within the
acceptable path range of 0
to 4. Verify the number of
paths and retry the operation.
The specified logical address
must be either 00 or 01.
Check the logical address
and retry the operation.
The specified link address
and port are already in use.
Check all existing logical
path addresses, and specify
another link address or RCP
port.
Check the serial number,
SSID, link address and
controller ID of the RCU, and
set the correct value. Then
retry the operation. If the
same error occurs, contact HP
technical support.
A maximum of four RCUs are
permitted, and that many
already exist.
Check the path connections
between the MCU and the
RCU, and then retry the
operation.
Check the path connections
between the MCU and the
RCU, and then retry the
operation.
Add another path, or delete
all pairs on the RCU. Then
retry the operation.
The specified number of
paths is less than the
minimum number of paths
specified on the RCU Option
window.
The version of the microcode
on the storage system does
not support the specified
function or operation. Call HP
technical support.
Add the normal paths, and
then set the minimum number
of paths.
Remote Web Console Error Codes 221
Severity
Failure
Level
Level
E
4
E
4
E
4
i
4
E
4
i
4
E
4
E
4
i
4
i
4
i
4
i
4

Hide quick links: