Table 54 Error Codes — Part Code 6505 (continued)
Part
Error
Code
Number
6505
58485
6505
58486
6505
58487
6505
58490
6505
58500
6505
58501
292 Remote Web Console for Storage System Messages and Error Codes
Error Message
The Add Pair (Paircreate)
operation failed because the
specified primary data
volume was one of the
following:
the specified volume was
a P-VOL of XP Snapshot
and was in Reverse Copy
status.
the specified volume was
an S-VOL of XP Snapshot.
The Paircreate operation
failed because the specified
primary data volume was a
V-VOL for XP Snapshot.
The Paircreate operation
failed because the specified
primary data volume was a
Pool-VOL.
Only the pair option of the
primary data volume was
updated. Failed to update the
pair option of the secondary
data volume.
The Add Pair (Paircreate)
operation failed because the
XP Continuous Access Journal
or the Universal Replicator for
Mainframe function of the
secondary subsystem does
not support external volumes.
The Paircreate operation
failed because the XP
Continuous Access Journal
function of the secondary
subsystem does not support
Data Retention Utility VMA.
Recommended Action
Confirm the state of the
specified primary data in the
XP Snapshot window.
Check the state of the
specified primary data
volume.
Confirm the status of the
specified primary data
volume.
A communication error
between the primary and the
secondary storage systems
occurred, or the microcode
of the secondary storage
system does not support the
change pair option function.
Check the main microcode of
the secondary storage
system, and call HP technical
support to confirm whether
the microcode supports the
change pair option function.
If the microcode supports the
function, call HP technical
support because a
communication error might
have occurred.
Check the DKCMAIN
microcode version of the
secondary storage system
and call HP technical support
to confirm whether the XP
Continuous Access Journal or
the Universal Replicator for
Mainframe function supports
external volumes.
Check the DKCMAIN
microcode version of the
secondary storage system
and call HP technical support
to confirm whether the XP
Continuous Access Journal
function supports Data
Retention Utility VMA.
Severity
Failure
Level
Level
W
5
W
0
W
5
W
0
W
5
W
5