Table 50 Error Codes — Part Code 6005 (continued)
Part
Error
Code
Number
6005
8973
6005
8975
6005
8976
6005
8977
6005
8980
6005
8982
6005
8983
6005
8984
6005
8985
6005
8986
6005
8987
6005
8988
242 Remote Web Console for Storage System Messages and Error Codes
Error Message
The operation failed because
the specified R-VOL was used
for Flex Copy XP.
Failed to create a pair,
because the specified R-VOL
is path-defined from the iSCSI
port.
A pair cannot be created,
because the specified M-VOL
is an external volume.
A pair cannot be created,
because the specified R-VOL
is an external volume.
The operation failed because
the licensed capacity of
Volume Retention Manager
on the RCU side was
exceeded.
You cannot create a pair,
because the specified M-VOL
is a command device.
You cannot create a pair,
because the specified R-VOL
is a command device.
You cannot create a new
pair, because the number of
CT groups of asynchronous
pairs that you can register in
SLPR exceeds the limit.
The coexistence of volumes
that are in the different CLPRs
is not allowed within one CT
group.
Cannot create a pair,
because the serial interface
is not supported by either the
MCU or the RCU.
Cannot create a pair,
because LUSE volumes
consisting of volumes from
different CUs are not
supported by either the MCU
or the RCU.
Cannot create a pair,
because LUSE volumes
consisting of volumes that
differ in capacity are not
supported by either the MCU
or the RCU.
Recommended Action
Check the status of the
specified R-VOL.
Check the status of the
specified R-VOL.
Check the status of the
specified M-VOL.
Check the status of the
specified R-VOL.
Confirm the licensed capacity
Volume Retention Manager
on the RCU side. To execute
this operation, purchase a
license key that allows you to
use a larger capacity.
Specify the volume that can
be used to create a pair, and
then retry the operation.
Specify the volume that can
be used to create a pair, and
then retry the operation.
Check the settings, and then
retry the operation.
Check the settings, and then
retry the operation.
Verify that both MCU and
RCU support the serial
interface.
Verify that both MCU and
RCU support LUSE volumes
that consist of volumes from
different CUs.
Verify that both MCU and
RCU support LUSE volumes
consisting of volumes that
differ in capacity.
Severity
Failure
Level
Level
i
4
i
4
i
4
i
4
i
4
i
4
i
4
E
4
i
4
i
4
i
4
i
4