Table 22 Error Codes — Part Code 0605
Part
Error
Error Message
Code
Number
0605
201 1
The status of the storage
system requires the
maintenance (for example,
the subsystem is blocked, the
shared memory is
inconsistent, or some other
factor). Call HP technical
support.
0605
2015
An error occurred while
connecting to the subsystem.
Wait for a while, and then
retry the operation.
0605
2085
Copying is in progress for XP
Continuous Access, Business
Copy, ShadowImage for
Mainframe, Auto LUN or
Compatible FlashCopy(R)
pairs. Please wait for a while,
and then retry the operation.
0605
2086
XP Continuous Access,
Business Copy,
ShadowImage for
Mainframe, Auto LUN or
Compatible FlashCopy(R)
pair is defined. Release the
pair definition, and then retry
the operation.
0605
2087
The system is online to the
mainframe host.
Take the subsystem offline
from the host.
0605
2088
The XP Continuous Access
pair is suspended. Add an
alternate path.
0605
2089
The corresponding CHA
might contain the last path
between the MCU and RCU
of XP Continuous Access.
Make sure that there is an
alternative path from the
MCU.
0605
2091
Business Copy,
ShadowImage for Mainframe
or Compatible FlashCopy(R)
is running. Please stop the
backup server and then retry
the operation.
0605
2095
Another maintenance
processing or failure handling
is in progress.
Recommended Action
Check the status of the disk
storage system (if the storage
system is blocked,
inconsistency of shared
memory, or some other
factor). If this problem
persists, call HP technical
support.
A communication error
occurs. If the error occurs
after retrying, call HP
technical support.
Wait a few seconds, and
then retry the operation.
XP Continuous Access, XP
Business Copy,
ShadowImage for
Mainframe, XP Auto LUN or
FlashCopy Mirroring pair is
defined. Release the pair
definition, and then retry the
operation.
Take the storage system
offline from the host.
Add an alternative path.
Be sure there is an alternative
path from the MCU.
Stop the backup server, and
then retry.
Wait a few seconds, and
then retry the operation.
Remote Web Console Error Codes
Severity
Failure
Level
Level
W
3
E
2
W
3
W
3
W
3
W
3
W
3
W
3
W
3
79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000

Table of Contents