Table 45 Error Codes — Part Code 5205 (continued)
Part
Error
Code
Number
5205
65712
5205
65714
5205
65715
5205
65716
5205
65736
5205
65737
5205
65738
5205
65739
5205
65748
208 Remote Web Console for Storage System Messages and Error Codes
Error Message
The specified plan cannot be
migrated, because the plan
is a combination of an
internal volume of OPEN-V
and a XP Thin Provisioning
volume of OPEN-0V.
The volume cannot be
migrated because the
configuration is being backed
up in the volume. Wait for a
while, and then retry the
operation.
Migration cannot be
executed because it is a
migration between an XP Thin
Provisioning volume and a
normal volume that contains
a component of a LUSE
volume.
The specified volume cannot
be set as a reserved volume.
Cannot migrate because the
source volume is a XP
Continuous Access
Asynchronous volume or
TrueCopy Asynchronous for
Mainframe volume, and also
the CLPR numbers of the
source volume and the target
volume are not the same.
The specified volume cannot
be used, because it is a
volume of XP Thin
Provisioning whose capacity
is being added.
The volume specified as a
migration target cannot be
used, because it is a volume
of XP Thin Provisioning that
is in the process of capacity
expansion.
The specified volume cannot
be used, because it is a
volume of XP Thin
Provisioning whose capacity
is being added.
The volume specified as a
migration source cannot be
used, because it is a volume
of XP Thin Provisioning in
zero data discarding.
Recommended Action
See the notes in the
Interoperability with Other
Products section in the HP
StorageWorks
XP24000/XP20000 Auto
LUN Software User's Guide
for the combination of the
volumes that cannot be
migrated.
Wait for a while, and then
retry the operation.
Check the setting of the
specified volume.
Check the setting of the
specified volume.
Check the setting of the
specified volume.
Check the specified volume
capacity after the completion
of the capacity expanding
operation.
Confirm the capacity of the
volume specified as a
migration target after the
capacity expansion operation
has completed.
Check the specified volume
capacity after the completion
of the capacity expanding
operation.
Retry the operation after the
zero data discarding
operation has completed.
Severity
Failure
Level
Level
E
6
E
6
E
6
E
6
E
6
E
6
E
6
E
6
E
6