Table 67 Error Codes — Part Code 8105 (continued)
Part
Error
Error Message
Code
Number
8105
1912
The specified volume is a
remote command device, and
therefore the command
device setting or the
command device security
setting cannot be set or
released.
8105
1918
An external volume is
mapped to the external port
to be operated. Delete the
external volume that is
mapped to the external port
to be operated, and then
retry the operation.
8105
1921
The specified volume is not a
LUSE volume.
8105
1926
The path cannot be set to the
specified volume, because
the volume is being used as
a quorum disk.
8105
1927
The specified volume cannot
be set as a command device,
because it is being used as a
quorum disk.
8105
2003
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
8105
2005
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
8105
2009
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
8105
2010
The LDEV is used by the
HOST, or an error occurred
in the server procedure.
8105
201 1
The status of the storage
system requires maintenance
(for example, the subsystem
is blocked, the shared
memory is inconsistent, or
some other problem occurs).
Call HP technical support.
8105
2013
An error occurred during SVP
processing. If this problem
persists, call HP technical
support.
Recommended Action
Correct the settings, and then
retry the operation.
Delete the external volume
that is mapped to the external
port to be operated, and then
retry the operation.
Check the volume, and then
retry the operation.
Check the setting.
Check the setting.
Use the SVP to check if the
DKC is in the normal status,
and then retry. If the same
problem persists despite
retrying, call HP technical
support.
If this problem persists, call
HP technical support.
If this problem persists, call
HP technical support.
Check if I/O from the host to
target path/volume does not
occur.
Check the status of the disk
storage system (for example,
the storage system is blocked,
the shared memory is
inconsistent, or some other
problem occurs). If this
problem persists, call HP
technical support.
If this problem persists, call
HP technical support.
Remote Web Console Error Codes 405
Severity
Failure
Level
Level
E
6
E
6
E
6
E
6
E
6
E
2
E
2
E
2
E
6
E
6
E
2

Hide quick links: