Crane Installation Procedures; The Mounting Plate And Boom - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

1.3

Crane Installation Procedures

1.3.1 The Mounting Plate and Boom

Tools required: Hex driver, 17mm socket wrench
Steps
1. Power down the OLP and disconnect its power plug.
2. Remove the four (4) hex screws (top) and three (3) hex screws (bottom) in
the top side panel on the right side of the OLP. Refer to Figure 1-2.
NOTE:
Later OLP models should have the mounting plate assem-
bly already in place.
3. If the Mounting bracket is not in place, use a 17mm socket wrench to
attach it to the frame. Use the four bolts, washers, and lock washers sup-
plied. Refer to Figure 1-2.
NOTE:
A 17mm socket is supplied to aid in securing the mounting
bracket.
4
Figure 1-2 Crane mounting plate assembly.
–Four panel hex screws (top). –Three panel hex screws (bottom).
–Four bolts with washers. –Mounting bracket.
1
3
Section V: Crane
2
Mounting 1-3