Avantra 36/44 Service Manual

3.1.6 Bridge Sensor Status

The bridge sensor status displays on the terminal when a Sensor Request command
(^F) is issued from the terminal. An "s" precedes the sensor status.
The sensor status is returned as a WORD value (two bytes). Each row of sensors (2
rows) are located in a separate byte. Row 1 (5 bits) is located in the lower byte; row
2 (5 bits) is located on the upper byte.
Sensors Located On Row 1 (Lower or Second Byte)
Sensors Located On Row 2 (Upper or First Byte)
3-6 Diagnostics
0001
Actuator Sensor
0002
Loop Sensor
0004
Bridge Purchase Sensor
0008
Shuttle - Bridge Mode Sensor
0010
Shuttle - Cassette Mode Sensor
0100
Unused Sensor
0200
Buffer Entry Sensor
0400
Buffer Purchase Sensor
0800
Buffer at Bridge Sensor (home)
1000
Buffer at Processor Sensor