9. Use the program to perform diagnostics, retrieve machine parameters, error
logs, download new firmware etc.
3.4.2.2
Exiting the Remote Connection
After completing the diagnostic session, the remote connection must be terminated.
Follow these procedures:
1. Complete or abort any operation currently under way.
2. Under EXIT, select the appropriate method of exiting.
Unless otherwise specified, always exit with a soft reset. Click on the Exit
with Reset button.
NOTE:
Resetting the system before exiting leaves the Avantra in a
known (idle) state. This helps to avoid confusion and pos-
sible problems to the customer later.
3. After transmitting the reset {MXRE} command to the Avantra, the program
issues a hang-up command to the modem. Make sure that the carrier detect
LED goes out, signaling that the connection has been terminated.
4. Call the customer site on the voice line to inform them that the Avantra is
back on line.
3.5

Vacuum System Troubleshooting Guide

The following is an aid to troubleshooting the Avantra 36/44 vacuum system. Refer
to the troubleshooting chart in Figure 3-2 when working with the following proce-
dures.
1. Turn the system on and allow the boot sequence to complete.
2. Using Avantra Diagnostics (AVDIAG), choose:
a. Align
b. Primitives
c.
Vacuum ON
At this point, the vacuum pump should be running.
3. If the pump fails to operate, check that both adjustment screws on the volt
sensing relay have been turned counterclockwise to MIN.
Refer to Figure 3-3 snd Section 3.5.1, Volt Sensing Relay Adjustment Proce-
dure below.