10. Using a P-clamp, secure the wires coming from the bridge/buffer interface
board on the right. Secure the P-clamp to the frame using a sems screw.
11. Using a P-clamp, secure the wires coming coming from the bridge/buffer
interface board on the left. Secure the P-clamp to the frame using a sems
screw.

1.5.6 Attaching the Ground Wires

Tools required: Screwdriver
1. Remove the sems screw in the P-clamp located under the shuttle motor.
2. Attach the two (2) ground wires to the bottom of the P-clamp. Refer to
Figure 1-22. Attach the hardware in the following order:
a.
star washer
b. ground cable eyelet
c.
ground cable eyelet
d. star washer
e. P-clamp (with wire bundle)
f.
hex screw
Section II: Bridge
Installation
1-21