46. Drain and remove the developer filter housing.
47. Install the Millipore Filter Cartridge supplied and re-install the housing.
48. Empty the replenishment containers.
49. Replace the overflow tubes, racks, crossover guides, and lids.
50. Put in the two (2) anti-evaporation covers (stainless steel) inside the racks.
Next place the front cover and the two (2) anti-oxidation covers. Refer to
Figure 1-26.
Figure 1-26 Anti-evaporation, front, and anti-oxidation cover locations.
–Anti-evaporation covers. –Forward top cover. –Anti-oxidation covers.