1
2
Dev
15%
P1-P9
28
27
26
Figure 4-2 New Control Panel with icon key pad
(Descriptions of keys on next page)
OLP Control Panel Icons (for Figure 4-2 )
1– Low Dev. or Fix.
8–Temp.
2–Display
9–Stdby Repl.
3–Low Repl.
10–Repl.
4–Waste Full
11–Up
5–Fix.
12–Preset
6–Dev.
13–Down
7–Time
14–On/Off
4.3.1 LUTH Motor Control Board (LMB) 24V DC (P/N
5202Y000100)
The LMB 24V performs the following functions:
Amplifies the motor preset value to the corresponding voltage for driving
the main motor
Receiving and converting /R pulse preset values (optical link)
Receiving and converting tacho feedback pulses
NOTE:
The following procedure is for OLPs with serial
#3613DD300659 and above. See Section 4.3.2 for calibrat-
ing the 180V LMB.
The following procedure calibrates the LMB (refer to Figure 4-3). A shorter remote
control panel cable is taped to the top of the electronics box to make the procedure
easier.
To Reposition the Control Panel:
1. Remove all power to the processor.
6
3
4
5
Dev
Fix
H
O
2
50%
85%
24
23
22
25
15–Enter
16–Man. Start
17–Man. Repl.
18–Dryer Saver
19–Auto
20–Panel Light
21–Dryer
Section IV: On-line Processor
7
8 9
11
12
10
21
20
18
17
19
16
22–Sound
23–Water
24–Film Feed Right
25–Exposure %
26–Dev. Temp. Incorr.
27–P1-P9
28–Film Feed Left
Maintenance 4-7