AGFA Avantra 36/44 Service Manual page 143

Table of Contents

Advertisement

Avantra 36/44 Service Manual
3.3.4.6
Program Bridge FLASHROM
Use this procedure to program the Bridge FLASHROM firmware from a PC into the
bridge's FLASHROM. The software to be loaded must reside in the Download
directory in the PC.
NOTE:
Prior to programming, the Bridge FLASHROM is automati-
cally erased.
1. Connect your PC to the diagnostic serial port of the system.
2. Turn the system on and allow the boot cycle to complete.
3. Next, launch the AVDIAG Program from your PC.
4. Under the FLASHROM menu, select Prog Bridge and press ENTER.
5. Select RAW and then the latest Bridge revision software.
6. Press ENTER.
A dialog box appears:
The following file has been selected to download to the Bridge FlashRom.
Select Y in the dialog box.
The system erases the Bridge FLASHROM and loads the new Bridge soft-
ware. When completed a dialog box appears:
Press any key to continue.
7. Press a key and wait for the system to reset.
3.3.4.7
Creating Correction Tables
The Avantra has twelve Correction Tables. Ten of the twelve tables are identical for
all Avantras (Avantra 20/25, Avantra 36/44, Avantra 36S/44S, and Avantra 30).
The two tables that are different for each system are the Density Variation (DQ)
files and the Linearity (L) files. The ten identical tables are called "Default Correc-
tion Tables". They are on the same program disk as the "DSP" main program.
Examples of some names for the Default Correction Tables are:
File Name
cor_12S.hex
cor_12CS.hex
cor_34S.hex
cor_34HS.hex
cor_30HS.hex
cor_12HS.hex
3-56 Diagnostics
Filename
Systems
Avantra 20/25 (DEC. B) boards
Avantra 20/25 (DEC. C) boards
Avantra 36/44
Avantra 36S/44S
Avantra 30
Avantra 25S