Avantra 36/44 Service Manual
2. Remove the black, input fan filter.
3. Hard vacuum the black filter.
4. Soft vacuum fan area.
5. Replace the black, input filter with a new one, if necessary.
6. Check the condition of the drum filter (Orange/White/Black) located on
the right drum light shield. This filter cannot be vacuumed.
7. Replace the drum filter with a new one, if necessary.
6.2.3.2
Supply/Take-up Cassette Area
To Clean:
1. Open the top cover and lift up the bridge, if installed.
2. Pull up and remove both supply cassette light shield covers.
3. Unload the media and remove the supply and take-up cassettes.
4. Using clear packing tape, clean the supply rollers (rotate the rollers until
their entire surface has been cleaned).
CAUTION: When cleaning the supply rollers, do NOT substitute any
other tape (i.e. , masking, duct tape, etc.) for clear tape. Substitutes
may leave a sticky residue on the roller, and any residue could
cause PERMANENT DAMAGE to the rollers.
5. Soft vacuum the following areas:
•
Supply trays
•
Under the supply drive rollers
•
Take-up platform
•
All accessible areas
•
Take-up labyrinth opening
6.2.3.3
Take-up Module Area
To Clean:
1. Remove the three bottom front covera.
2. Remove the take-up cover light shield.
3. Remove the outer take-up nip assembly.
4. Soft vacuum:
•
All assembly surfaces including punch and cutter assemblies
•
Area below drum
•
Nip drive rollers, using clear tape
6-6 Maintenance