4. Under the ALIGN menu, select OCP User Parameters and press ENTER.
A dialog box appears:
Loading OCP EEPROM User Parameters and OCP EEPROM Cassette
Parameters into memory.
Select Y in the dialog box.
The OCP parameters load up to the PC.
5. When the load completes, select Save to File.
A dialog box appears:
OCP EEPROM User and Cassette Parameters to be saved to a file.
Select Y in the dialog box.
6. A dialog box appears for Pathname/Filename. Press ENTER.
7. The Pathname/Filename appears in the dialog box using the system serial
number and extension. Press ENTER.
The OCP user and cassette parameters are saved to a file.
To Restore:
1. Connect your PC to the diagnostic serial port of the system.
2. Turn the system on and allow the boot cycle to complete.
3. Launch the AVDIAG Program from your PC.
4. Under the Align menu, select OCP User Parameters and press ENTER.
A dialog box appears:
Loading OCP EEPROM User Parameters and OCP Cassette Parameters
into memory.
5. Select N and then Restore to Engine.
6. A dialog box appears with all the saved OCP files. Select the file with the
same serial number and OCP extension saved in Step 7 in the save proce-
dures above.
7. The OCP User and Cassette Parameters will be restored to the imagesetter.
When the process completes, a dialog box appears:
Values will not take effect until engine reset.
Select Y and wait for imagesetter to reset.