5. Pop in the button plugs at the top of the bridge, left and right side. Refer to
Figure 1-14.

1.5.3 Adjusting the Detent Plate

Tools required: Screwdriver
Steps
1. Open both side doors on the imagesetter by loosening the thumb screws
on the inside. Refer to Figure 1-15.
2. Remove the two (2) plastic access panels at the top of the imagesetter.
This gives easier access to the detent plates.
3. The bridge must be in the down position for this procedure.
1-14
Installation
1
Figure 1-14 Placing the button plugs.
–Bridge. –Button plug (one of two).