Slack Loop Test Procedure - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

5.14 Slack Loop Test Procedure

NOTE: The slack loop test works only for thin media (4 mil and
under). It is disabled for thick media (over 4 mil).
The slack loop test is used to determine the adjustment setting of the slack loop
flag as well as the speed of the bridge and take-up motors, based on the number
of times the slack loop is formed during a feed of a given length. The test is
performed as follows:
1. The slack loop test function is located on the Secret Screen of the Avantra
Control Panel. Press the proper key sequence on the "Configuration"
Screen to enter this special screen. Refer to Figure 5-6.
1
1
B
2
ROW
3
B
4
5
A) Press button 5,2 first
B) Press button 1,3 twice
C) Press button 5,2 again
NOTE: If there is an icon in location 5,2, use location 5,3.
2. Locate the key marked "Slack Loop Off" on the Secret Screen. Pressing this
key will toggle the slack loop test function on and off. After enabling the
slack loop test, exit the screen. Refer to Figure 5-7.
COLUMN
2
3
4
in/ft
B
B
Figure 5-6 The Secret Screen.
or
Section I: Imagesetter
5
6
B
B
A) Press button 5,3 first
B) Press button 1,3 twice
C) Press button 5,3 again
A, C
Alignment 5-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avantra 36s/44s

Table of Contents