Replace:
1. Reverse the procedures above.
CAUTION:
When replacing the sensors, make sure that the flags
enter the sensors at the correct point. Refer to Figure 2-2.
2.3

Buffer Purchase Sensor

The following describes how to remove and replace the purchase sensor.
Tools Required: 1/4" open end wrench
Remove:
1. Remove the top cover from the buffer.
2. Disconnect the connector from the sensor. Refer to Figure 2-2.
3. Remove the two (2) 1/4" hex nuts securing the sensor.
Figure 2-2 Buffer purchase sensor.
–Carriage drive motor. –Lead screw. –Buffer purchase sensor.
Replace:
1. Reverse the procedures above.