AGFA Avantra 36/44 Service Manual page 257

Table of Contents

Advertisement

Avantra 36/44 Service Manual
6.2.1.1
General Inspection
Inspection consists of the following procedures:
1. Disconnect the AC power cord from the wall receptacle.
2. Remove the front cover. Remove the rear cover, if the system is not
attached to a buffer.
3. Swing open the side doors on both ends of the system.
4. Inspect the system for the following conditions:
Damage to outer panels (note panel condition)
Damaged, missing, or loose hardware and connectors
Loose or damaged cables and line cords
Proper wire harness and cable routing
Damaged components
5. Do the following:
Carriage rail cleaning
Spin motor cleaning
Punch remnants removal
The following explains how to perform these three procedures.
6.2.1.2
Carriage Rail Cleaning Procedure
Periodic cleaning of the carriage rails keeps contamination out of the roller
bearings and keeps rust from building up on the rails. Excessive build-up of
contamination could result in copy artifacts.
Tools Required: Optic Pads (P/N 78047-002)
To Clean:
1. Swing open the side door on each end of the system.
2. Remove the drum light shields to gain access to both sides of the carriage
assembly.
3. Line the drum with a piece of cut media to catch any contamination that
may fall during the cleaning procedure.
4. Gently slide the carriage assembly away until it reaches the other end.
5. Using an optical wipe, clean the rails. Remove all the contamination. As
much as possible, clean contamination from other exposed surfaces.
6. Move to the other end of the system and perform the previous step on the
rails.
6-2 Maintenance

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avantra 36s/44s

Table of Contents