AGFA Avantra 36/44 Service Manual page 139

Table of Contents

Advertisement

Avantra 36/44 Service Manual
To Restore:
1. Select FLASHROM and then Prog DSP/CORR.
2. Select RAW.
3. Select the filename saved in Step 9.
This was the DSP file saved in the save procedures above.
4. Select the correction table for this system that was saved in Step 6 above.
A dialog box appears with the two files previously selected to be down-
loaded to the DEC FLASHROM.
5. If the files are the correct ones for this system, press ENTER.
The system erases the DEC FLASHROM and loads the two files selected:
DSP code
Correction Table
6. When the load completes, press any key and wait for the Avantra to reset.
3.3.4.3
Save/Restore Operator's Control Panel (OCP) User
Parameters
Use this procedure to save OCP user parameters to the PC or restore OCP user
parameters from a PC back to the system. The parameters being saved/restored
reside in the OCP micro-controller's EEPROM and include:
User parameters
Cassette parameters
Operational statistics
To Save:
1. Connect your PC to the diagnostic serial port of the system.
2. Turn the system on and allow the boot cycle to complete.
3. Launch the AVDIAG Program from your PC.
3-52 Diagnostics