Save And Restore System Parameters - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

3.3.4 Save and Restore System Parameters

3.3.4.1
Save/Restore DEC Machine Parameters
Use this procedure to save DEC machine parameters to the PC or to restore DEC
parameters from a PC back to the system. The parameters saved/restored reside in
the DEC micro-controller's EEPROM and include:
Image/Focus Parameters
Media Parameters
DSP Parameters
To Save:
1. Connect the PC to the diagnostic serial port of the system.
2. Turn the system on and allow the boot cycle to complete.
3. Launch the AVDIAG Program from your PC.
4. Under the ALIGN menu, select DEC Machine parameters and press ENTER.
A message appears querying whether the machine parameters should be
loaded. Press Y.
The parameters load from the system into the PC's memory. A dialog box
appears with a list of actions that can be performed.
5. Select Save to File and press ENTER.
Another dialog box appears:
Dec. Machine Parameters to be saved to a file.
Select Y.
6. A dialog box appears for Pathname/Filename. Press ENTER.
7. The Pathname/Filename appears in the dialog box using the system's serial
number and extension. Press ENTER.
The machine parameters are saved.