2. The "T-Compress Speed" is really the compression speed for both supply
and take-up servo motors. The supply servo uses a percentage of the "T-
Compress Curr" value. The percentage amount is specified in the "S Cmp
Curr Rtio" field, which has a default of 50 (50%). So if:
T-Compress Curr = 24
T-Compress Speed = 6
S Cmp Curr Rtio = 50
Then the take-up servo runs at a speed of 6 and a current of 24. The sup-
ply servo runs at a speed of 6 and a current of 12.
NOTE:
Write new values to the imagesetter by typing in the appropriate parameter. Listed
below are the media parameters, ranges and definitions.
Media Parameter
Supply Motor Feed Current
Supply Motor Comp Current
Supply Motor Comp Speed
Supply Feed Speed
Supply Hold Speed
Supply Hold Current
Supply Rewind Current
Supp/Tkup Delay*
Media Settle Delay
Nip Delay
Image Feed Length
S-Spind Fwd Assist
The above values may be different depending on the revi-
sion of software in your system. Refer to the Customer Ser-
vice Bulletin (CSB) for the correct values for that revision of
software.
Range
(0 - 255)
(0 - 255)
(0 - 255)
(0 - 255)
(0 - 255)
(0 - 255)
(0 - 255)
0 - 100 take-
up motor
starts before
supply motor
101 -200
supply
motor before
servo
(0 - 999)
(0 - 100)
(0 - 3600)
Definitions
Current of supply motor during feed.
Current of supply motor during compression.
Speed of supply motor when going into compression.
Speed of supply motor during feed.
Supply hold speed for punchless systems.
Supply Hold Current for punchless systems.
Current of supply cassette motor during rewind.
The start-up delay time between the take-up servo and
supply servo motors. Default is 0 (zero), which indicates
that the delay time parameter is not being used.
Settling time of media.
Delay after Nips are open/closed.
Image feed length from AVDIAG.
The supply spindle forward assist current, which is the
amount of current applied to the supply cassette revind
motors in the forward direction. Used at the beginning of
all supply and image feeds. Default is 50 (fifty)).