11. Check the other three PWM files.
When completed you should have four values, one for each resolution.
NOTE: Some of the text, especially the PWM@18.FIL, does not line
up correctly with the patterns. Look at one of the other
PWM files for correct positioning of text.
12. Exit the PC Imager program and launch the AVDIAG program from thePC.
13. Select Align and then DEC Machine Parameters.
The following dialog appears:
Loading Dec. Machine Parameters.
14. Select Y in the dialog box to load the parameters to memory.
15. Select DEC (Image/Focus) and move the cursor down to change the PWM
values selected in Steps 9 and 10 for all four resolutions.
16. Press ESC.
17. Exit AVDIAG with a soft reset.
Figure 5-2 Reference exposure patterns.
(These patterns are only a simulation.
They are meant to be used as a guide in selecting a correct value.)
Section I: Imagesetter
Alignment 5-13