AGFA Avantra 36/44 Service Manual page 110

Table of Contents

Advertisement

MEDIA TESTS
NOTE:
To actually see the motors moving, you need to run these
tests in continuous mode with a pass count of 10.
Test
Cutter
Take-up Punch
Supply Punch
Nip Solenoid
Spd. Selector
Spd. Motor A
Spd. Motor B
*
Supp Feed Motor
**
Tkup Align Motor
***
Flappers
Brushes
* This motor will only turn off if the media sensor is covered or errors are turned off.
** Take-up cassette must be in system for this test to pass.
*** If the carriage is not centered on the drum, the flappers will be damaged.
OCP TESTS
Test
FLASHROM Checksum
Function
Executes a Media take-up Punch
Execute a Head Clamp-Punch-Home sequence
Execute a Tail Clamp-Punch-Home sequence
Open-Close Nips
Moves from one spindle to the other
Turns Spindle Motor A On/Off
Turns Spindle Motor B On/Off
Turns Feed Motor On/Off
Turns Align Motor On/Off
Cycles flappers down and up
Cycles brushes up and down
Function
Display Additive checksum of the OCP FLASHROM
Section I: Imagesetter
Diagnostics 3-23