Cutter Assembly - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

Avantra 36/44 Service Manual
7. Remove the two (2) 3/16" hex bolts securing the take-up punch assembly
to the outer drum surface. Refer to Figure 4-13.
8. Remove the punch assembly from the system.
Replace:
1. Install the punch assembly to the scribe marks. Refer to Figure 4-13.
2. Move the take-up punch assembly completely to the right until it touches
the punch shoe. Tighten the two (2) 3/16" allen screws.
3. Reverse the above removal procedures starting with Step 10.
4. After installing the outer take-up drive assembly, turn the system on and
launch the AVDIAG program from your PC.
5. Select Test and then Selectable Test.
6. Select Media Tests and then Take-Up Punch.
The take-up punch should move and pass the test.
7. Insert a piece of film from the drum surface to the punch assembly. Push it
in to the punch and check that it moves freely without getting jammed.
NOTE: The punch opening should not be extended beyond the
drum surface.

4.3.7 Cutter Assembly

Tools Required: 5/16" nut driver with extension, allen wrench .050, screwdriver
Remove:
1. Remove the outer take-up drive (nip) assembly. See Section 4.3.2, Outer
Take-up Drive (Nip) Assembly.
NOTE: The inner take-up drive (nip) assembly can remain in place.
2. Open the right side cover. See Section 4.2.1, Right/Left Side Covers.
3. Disconnect the power cable located near the SDM board on the right side
of the imagesetter.
4. Remove the switch/sensor connector (J4) from the take-up SDM board.
Refer to Figure 4-14.
4-20 Removal and Replacement