Vacuum Pump - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

4.8.1 Vacuum Pump

Tools Required: Flathead and phillips screwdrivers
Remove:
1. Open the right side cover. See Section 4.2.1, Right/Left Side Covers.
2. Remove the two (2) tubing fittings from the pump. Refer to Figure 4-49.
3. Using a flathead screwdriver, remove the two (2) mounting plate screws.
Refer to Figure 4-49. Remove the plate with the pump on it.
4. Using a phillips screwdriver, remove the screw holding the grounding wire
in place. Refer to Figure 4-49.
5. Turn the pump on its side and disconnect the connector at the bottom of
the plate. Refer to Figure 4-49.
3
4
–Tubing fittings. –Rubber feet. –Ground wire. –Mounting plate.
–Two mounting plate screws. –Connector (under mounting plate).
1
2
5
Figure 4-49 Vacuum pump.
–Valve assembly.
Section I: Imagesetter
6
Removal and Replacement 4-69
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avantra 36s/44s

Table of Contents