AGFA Avantra 36/44 Service Manual page 117

Table of Contents

Advertisement

Avantra 36/44 Service Manual
Parameter
BOL Offset..........
Carriage Home.....
PWM @1200.......
PWM @1800.......
PWM @2400.......
PWM @3600.......
Magnification.......
Linearity.............
SlowScan MAG...
SlowScan PHASE
SlowScan CONST
Vacuum Control...
1st Ramp Steplgth
1st Ramp Spd......
* System dependent
NOTE:
The above values may be different depending on the revi-
sion of the software loaded into your system. Refer to the
CSB (Customer Service Bulletin) for the current values for
that version of software.
3-30 Diagnostics
DEC (Image/Focus/Bridge)
Value
Parameter
*
Polarizer Home....
*
Focus Position.....
*
Focus Steps/Mil...
*
Focus Motor Rate
*
Polarizer Rate......
*
Spot Motor Rate...
*
Beam Comp Rate
*
Beam Comp Offse
*
0
0
1
Film Brush Ctrl...
100
Paper Brush Ctrl...
Plate Brush Ctrl...
Value
Parameter
*
Brdg Max. Torque
*
Buffer Med Spd.....
22
Bridge On Delay....
15300
Ubr FastSp Thin...
1600
Ubr SlowSp Thin..
4500
Lbr SlowSp Thin...
1600
Lbr SlCurr Thin....
*
BrOffElyTimThin
Ubr FastSp Thick...
Ubr SlowSp Thick
Lbr SlowSp Thick
Lbr SlCurr Thick...
BrOffElyTimThick
4
22
22
Value
250
11421
1
4500
6500
62
70
90
5500
5500
62
70
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avantra 36s/44s

Table of Contents