1.1
Introduction
This chapter describes the requirements and procedures necessary for installing the
Avantra 36/44 imagesetter.
Included in this chapter are:
•
Customer Pre-site Checklist
•
Service Engineer Installation Procedure
•
Pre-installation Checks
•
Upacking the Imagesetter
•
Unlocking the Imagesetter
•
Checking the System
•
Customer Application Training
1.2
Customer Pre-site Checklist
The customer should use the following pre-site checklist to ensure that the intended
installation site is properly prepared to receive and install the Avantra 36/44 image-
setter.
•
Power Requirements
The customer must provide a separate (isolated) three wire 115/230 VAC
grounded power line. The wires can be run in conduit, but the conduit
cannot serve as a ground. The receptacle type must be a 2 pole, 15 amp
grounded, NEMA 5-20R or equivalent. Electrical specifications for the
imagesetter are:
Volts:
Amp:
Rec:
Power:
Heat Output:
115/230
5 / 2.5
NEMA 5-20R
575 Watts
1962 BTU's
Chapter 1:
Imagesetter
Installation
Procedures
1-1