AGFA Avantra 36/44 Service Manual page 190

Table of Contents

Advertisement

5
7
Figure 4-21 Operator control panel (OCP).
–Power cord clamp. –Removable mounting bracket's 1/4" hex screw.
–1/4" hex screws (2) securing OCP ribbon cable bracket.
–Power supply connector.
–OCP ribbon cable. –Removable mounting bracket's 5/16" hex screw.
4. Remove the hex screw securing the power cord clamp to the electronics
enclosure. Refer to Figure 4-21.
5. Remove the power connector located below the control panel.
6. Remove the power connector going to the power supply. Refer to
Figure 4-21.
7. Loosen the 1/4" hex screw securing the OCP assembly to the removable
mounting bracket. Refer to Figure 4-21.
8. Remove the 5/16" hex screw securing the removable mounting bracket to
the electronics enclosure. Refer to Figure 4-21.
1
3
2
–AC power connector.
Removal and Replacement 4-31
Section I: Imagesetter
4
6

Advertisement