Avantra 36/44 Service Manual
2.2
Buffer Home and Buffer Processor
Sensors
The following describes how to remove and replace the home and/or buffer
processor sensors.
Tools Required: 1/4" open end wrench
Remove:
1. Remove the top cover from the buffer.
2. Disconnect the connector(s) from the sensor(s). Refer to Figure 2-1 for
identification.
3. Remove the 1/4" hex nuts securing the sensors.
–Home sensor (bottom) and buffer processor sensor (top) with connectors.
2-2 Removal and Replacement
1
Figure 2-1 Buffer sensors and flags.
–Sensor flags.
–Buffer carriage.
2
3