AGFA Avantra 36/44 Service Manual page 125

Table of Contents

Advertisement

Avantra 36/44 Service Manual
Firmware Revisions
Selecting Firmware Revs displays a dialog box that lists the firmware revision levels
installed in the imagesetter currently connected.
DEC Firmware (K4/K1 FlashROM
DSP Firmware (DEC FlashROM)
OCP Firmware (OCP FlashROM
OCP Download (OCP EEPROM)
Diagnostic Firmware (C9)
Correction Table Version-Type
Bridge/OLP (OLP FlashROM)
* The revision levels change from release to release.
Display Error Log
Selecting Error Log displays a dialog box that shows a scrolling list of errors logged
in the imagesetter. The error log contains the last 64 errors (both boot and applica-
tion) encountered by the system. If the system supports real-time clock then only
the last 30 errors will be displayed. The error codes are in DEC EEPROM. The soft-
ware retrieves the error log from EEPROM upon entering this menu selection. Clear
the error log by pressing ALT C. A typical error log is shown below.
Index
Error
====================================================================
000
037
001
01
* If the system does not support real-time clock then the Error Log will display "Media" instead of date
and time.
3-38 Diagnostics
Avantra Firmware Revisions
AVANTRA ERROR LOG
Date*
Time*
Description
11-21-96
10:16
Output Cassette Jam/Blocked Sensor
11-07-96
15:50
Carriage Jam
:
*
:
*
:
*
:
*
:
*
:
*
:
*