AGFA Avantra 36/44 Service Manual page 235

Table of Contents

Advertisement

8. Continue to enter new BOL position values until the scan line centers
between the supply and take-up punches on the drum surfaces.
NOTE: A BOL position value change of 1000 represents an
(approximately) one (1) inch movement on the drum's sur-
face. Lowering the BOL position value moves the scan line
counter-clockwise.
9. The BOL position value is temporary. After determining the correct value, it
must be stored in the DEC's EEPROM (DEC Machine Parameters).
10. Press ESC to exit the SGM-A/B Mod Align menu.
NOTE: If the resolution needs to be changed, all parameters must
be re-entered and the Beam On must be selected again.
This is to recalculate the parameters for the new resolution.
If not done, unpredictable BOL positions can be expected.
11. Select DEC Machine Parameters.
The following dialog appears:
Loading DEC EEPROM Machine Parameters.
12. Select Y in the dialog box to load the parameters into memory.
13. After loading completes, select DEC Image/Focus. cursor down to the BOL
Offset parameter field and press ENTER. Enter the new BOL offset value
determined in Step 8 and press ENTER.
The value loads into EEPROM.
Fine Alignment:
NOTE: Check the Distance to Punches parameter in the Feed
Amount Screen prior to running copy. The parameter could
effect the starting point for BOL.
1. Turn the system off. Insure all covers and shields are in place. Turn the
system back on.
The system loads and uses the new BOL offset value from EEPROM.
2. Connect the system's Agfa Print Engine Interface Standard (APIS) cable to
the PC imager board in your PC.
3. Start the PC Imager from the PC.
NOTE: Refer to the PC Imager User's Manual (P/N 580024-001) for
detailed information on running this utility.
Section I: Imagesetter
Alignment 5-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avantra 36s/44s

Table of Contents