Defaults:
Resolution will be set to 3600
Gate Start to 0
Gate Length to 25
Aperture to 3600. The resolution will automatically change to the
aperture's value.
Carriage Alignment
This menu item allows the alignment of the carriage encoders. This function exe-
cutes a test on the DSP, reads in the values resulting from that test, displays the val-
ues, and calculates new encoder constants and writes the new encoder constants to
DEC EEPROM. The user should reboot the imagesetter after running this test. To
view new values, load down DEC Machine Parameter and select DEC (Plate/DSP).
DEC Machine Parameters
NOTE:
To view the following parameters you must first load down
the DEC machine parameters. See Section 3.3.4.1
Image/Focus
Selecting Image/Focus displays a dialog box that shows the current image and
focus parameters stored in the imagesetter. These parameters reside in DEC
EEPROM. The software retrieves these parameters from EEPROM upon entering
this menu selection. Listed below are the image and focus parameters, ranges and
default values.
Section I: Imagesetter