Circulation Pump - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

Avantra 36/44 Service Manual
3.7

Circulation Pump

The following describes how to remove and replace the circulation pump.
Tools Required: Flathead screwdriver, open end wrench
Remove:
1. Turn off and unplug the OLP.
2. Remove the top and side covers.
3. Drain the tank.
CAUTION: Even with the tanks drained, chemistry will remain in the
hose connections. Wear rubber gloves and have rags ready for spill-
age before proceeding to the next step.
4. Using a flathead screwdriver, loosen the hose clamps securing the two (2)
hoses to the pump. Refer to Figure 3-11. Remove both hoses.
1
–Hose clamps. –Circulation pump. –Power lines (electrical connection).
5. Follow the black, white and green power wires (electrical connection) to
the terminal block and disconnect. Refer to Figure 3-11.
NOTE: Note the wire positioning for proper replacement.
3-14 Removal and Replacement
Figure 3-11 The circulation pump.
–Mounting plate.
2
4
3

Advertisement