4. Select Test and then Selectable Test.
5. Select Media Test and then Cutter.
The cutter should make one revolution and pass the test.
4.3.9 Take-up Media Present Detector
Tools Required: 3/4" nut driver, small screwdriver, 3/16" wrench
Remove:
1. Remove the cutter assembly. See Section 4.3.7, Cutter Assembly.
2. Position the cutter assembly so that the cutter motor is to the right and the
mounting plate (the plate that attaches the cutter assembly to the drum) is
facing down. Refer to Figure 4-16.
Figure 4-16 Take-up media present sensor.
–Cutter assembly. –Take-up media present sensor.
–Sensor connector. –1/4" hex nut. –Mounting plates.
3. Remove the connector from the media present sensor. Refer to Figure 4-16.
4. Using a 1/4" open end wrench, remove the hex nut securing the media
present sensor. Refer to Figure 4-16.
4
1
Section I: Imagesetter
2
3
5
Removal and Replacement 4-23