Write new values to the imagesetter by typing in the appropriate parameter. Listed
below are the parameters and defaults.
Bridge Max Torque
Buffer Med Spd
UpBrdg Fast Spd
UpBrdg Slow Spd
LwBrdg Slow Spd
LwBrdg Slow Curr
BrdgeOffEly Time*
*This value must be set larger than the NipsOpEly Time field.
Media
Selecting Media displays a dialog box that shows the current media parameters
stored in the imagesetter. These parameters are in DEC EEPROM. The software
retrieves the parameters from EEPROM upon entering this menu selection.
NOTE:
Some of the values below may change from system to sys-
tem.
The maximum torque of the upper bridge motor.
Defaullt is 250. Increasing the calue increases the
torque.
The buffer medium speed, which controls how fast
the media is delivered from the buffer to the first set
of input rollers on the processor. Default is 11421.
Increasing this value decreases the speed.
The fast speed of the upper bridge motor, which
properly maintains the slack loop. Default is 4500 thin
and 5500 thick. Increasing the value decreases the
speed.
The slow speed of the upper bridge motor, which
properly maintains the slack loop. Default is 6500 thin
and 5500 thick. Increasing this value decreases the
speed.
The slow speed of the lower bridge motor (Take-Up
Cassette Core motor), which properly maintains the
slack loop. Default is 62 both thin and thick. Increas-
ing this value increases the speed.
The current of the lower bridge motor (Take-Up Cas-
sette Core motor), which properly maintains the slack
loop. Default is 70 for both thin and thick. Increasing
the value increases the torque.
The bridge motor turn off just prior to the feed servo
motors, which maintains the slack loop. Default is 50
thin and 20 thick. Increasing this value increases the
torque.