The Bridge Up Sensor - AGFA Avantra 36/44 Service Manual

Table of Contents

Advertisement

4.7

The Bridge Up Sensor

Tools: Phillips head screwdriver
Remove:
1. If the bridge foot is on, put the system in light mode and turn the system
off.
2. Using a phillips head screwdriver, remove the six (6) holding screws from
the bridge side cover on the right. Refer to Figure 4-2.
3. Remove the connector from the bridge up sensor. Refer to Figure 4-5.
4. Remove the sensor connector. Refer to Figure 4-5.
5. Using a 1/4" open end wrench, remove the two (2) nuts securing the sen-
sor to the cover. Refer to Figure 4-5.
1
2
–Bridge up sensor. –Side cover. –Securing nuts.
Replace:
1. Reverse the procedure above.
3
Figure 4-5 Bridge up sensor.
–Sensor connector.
Section II: Bridge
4
Removal and Replacement 4-7